Fire and Life Safety Requirements for STRs
No Nashville rental permit is issued before an inspector signs off on four things: the smoke alarms, an escape window in each bedroom, visible street numbers and an accurate floor plan. This page covers what the inspection looks for, who may perform it, the occupancy limits that come with the permit, and the state rules that decide how a large rental house is classified. Sources were read on November 12, 2026.
- Code the permit points to
- State and local building and fire codes (Metro Code 6.28.030)
- Metro fire code
- 2024 International Fire Code and NFPA 101, adopted by BL2025-1004 (Oct. 2025)
- Smoke alarms
- UL 217, interconnected, in every sleeping room, the path out and every story
- Inspector, house or duplex
- State-licensed architect, engineer or home inspector
- Inspector, common hallway or 3+ dwellings
- Nashville Fire Marshal's Office
- Bedrooms and guests
- Four sleeping rooms at most; 12 occupants at most
- Checked
- November 12, 2026
On this page
- Which codes apply
- Smoke alarms
- Bedroom escape windows
- Street numbers
- The floor plan and the inspection report
- Who performs the inspection
- Bedrooms, guests and what gets posted
- When the state treats a rental house as a commercial building
- Grills and open flames
- Keeping the unit inspection-ready
- Who to confirm with
- Questions
- Sources
Which codes apply
Metro's rental chapter, 6.28, ties both permit types to whatever building and fire codes, state and local, would govern the dwelling anyway. Metro Codes repeats that line on its operating rules page, and the permit application turns it into a short list of things an inspector must confirm before the permit is issued.
Metro's fire code changed in 2025. The Council passed BL2025-1004 on October 9, 2025, adopting the 2024 International Fire Code and the 2024 NFPA 101 Life Safety Code with local amendments, effective on passage. Before that, Nashville had used the 2018 NFPA 1 Fire Code under BL2021-658. One of the 2025 amendments says that where the fire code does not address something in an existing building, NFPA 101 governs.
Smoke alarms
The alarm rule is the one inspectors spend the most time on. Chapter 6.28 names three places for UL 217 alarms: each sleeping area, each room a sleeper would pass through on the way to the unit's exit, and every level of the unit down to the basement. Metro Codes' application page adds garages to that list.
For houses and duplexes, Metro's inspection guidelines hold even a century-old home to 2018 standards for where alarms go and how they link together, and they send inspectors to R314 of the 2018 residential code for the details. Interconnection means that when one alarm sounds, all of them sound. Those guidelines are dated June 2023, and Metro has since moved its building codes to the 2024 editions, including the 2024 residential code, through BL2025-898, passed July 15, 2025. Ask your inspector which edition the certification will be checked against.
The 2025 Metro fire code rewrote its own residential alarm section for Groups R-2, R-3 and R-4. It requires alarms outside each separate sleeping area near the bedrooms, in each room used for sleeping, and on each story of a dwelling unit including basements, garages and cellars, but not crawl spaces or attics no one uses. Heat detectors may stand in for smoke alarms in cellars and attached garages.
Age matters too. Tennessee's State Fire Marshal rule for one- and two-family dwellings, as amended effective February 25, 2024, says smoke alarms may be no more than ten years past their manufacture date, and battery-only devices must use a ten-year sealed battery. Check the date printed on the back of each alarm before the inspection.
Bedroom escape windows
Bedroom windows are the second item the guidelines hold to 2018 standards no matter when the house was built. A June 2, 2022 update from the Fire Marshal, quoted in the guidelines, accepts bedroom windows that were approved at the final use and occupancy inspection for the structure.
The Fire Department's applicant checklist gives the working numbers. In each bedroom, one window has to open fully and leave a hole of at least 820.8 square inches, which is 5.7 square feet, measuring 20 inches across and 24 inches tall at minimum, with its lower edge 44 inches or less off the floor. Ground-floor bedrooms get by with 720 square inches, and a bedroom that has an exterior door of its own is excused from the window test. The checklist cites the 2012 fire code, so confirm the numbers with the Fire Marshal's Office now that the 2024 edition is in force.
Measure the opening only, not the sash or frame. Painted-shut sashes, security bars without a quick release and window air conditioners all block the opening an inspector measures.
Street numbers
Inspectors check that emergency crews can find the door. The single and two-family guidelines ask for contrasting numbers at least 3 inches tall on the building or the mailbox. The 2025 Metro fire code sets the same 3-inch minimum for residences, adds a half-inch stroke width, requires Arabic numerals rather than spelled-out words, and allows the mailbox only when it sits by the street.
The Fire Department's older checklist asks for numbers at least 4 inches tall. Numbers of 4 inches or more satisfy both documents.
The floor plan and the inspection report
The application needs a drawing for every level of the unit that marks each room, door, window and alarm. Metro accepts an official or a hand-drawn plan, and its checklist for not-owner-occupied permits asks for letter-size paper. The guidelines say a basic, accurate plan is enough, and that the inspector either verifies a plan the owner provides or draws one.
For houses and duplexes, the report must carry the inspector's stamp, seal or signature and date on each page, along with the license number. Metro Codes links to the state's license lookups for architects, engineers and home inspectors, so confirm the license before you hire.
Who performs the inspection
The route depends on the building. A detached house or a duplex is certified by a private professional, licensed in Tennessee in one of three fields (architecture, engineering or home inspection), and the permit waits until that signed certification reaches the file.
Apartment and condominium buildings go to the Fire Marshal instead. Metro's shorthand is about the front door: a unit reached through a shared corridor or walkway gets the Fire Marshal. On Metro's checklist for absentee-owner permits, a parcel with three dwellings or more goes to the Fire Marshal. Our page on multi-unit buildings covers that process.
Bedrooms, guests and what gets posted
Four bedrooms is the most a permitted unit may have; Metro Codes turns away a fifth. Guest count follows a formula, two per permitted bedroom and four more, topping out at 12.
Inside the unit, a notice has to show the guest limit and the name and number of the local contact person. The responsible party has to answer calls around the clock for every stay. Only a single booking group may hold the unit on any night, led by a renter aged 21 or older.
| Sleeping rooms | Most occupants allowed |
|---|---|
| 1 | 6 |
| 2 | 8 |
| 3 | 10 |
| 4 | 12 |
When the state treats a rental house as a commercial building
Tennessee's State Fire Marshal's Office has its own way of sorting homes rented for 30 days or less, which it calls transient rental homes. A memo from that office dated April 13, 2023 restates the line it has drawn since February 2016. Three stories or fewer, a gross area below the 5,000-square-foot mark, and a dozen sleepers at most: a rental house meeting all three is treated as an ordinary dwelling that may use the home sprinkler exemption. Cross any one of those lines, a fourth story, 5,000 square feet, or a 13th guest, and the memo moves the house into Group R-3 under the commercial building code, with no sprinkler exemption.
The memo counts finished or occupied basements in gross square feet. Under the memo, a basement turns into a story once the floor over it rises above the averaged grade by more than 6 feet, or tops 12 feet over the ground at any single spot. The office traces the policy to a fatal April 2014 blaze with multiple victims at a rental, after which it found big rentals in parts of the state that had wrongly been built to the code for ordinary houses.
Metro's 12-occupant ceiling keeps a permitted unit on the residential side of the occupant test. Floor area and story count are separate tests, so a large house with a finished basement can still land in the R-3 group. The memo says local building and fire officials regulate those houses where a city or county holds a state exemption, and the state regulates them elsewhere, so ask Metro Codes which applies before you buy a big house.
Grills and open flames
The 2025 Metro fire code bars hibachis, grills and similar open-flame devices on balconies, under overhangs and within 10 feet of a structure, but that section exempts one- and two-family dwellings. A separate amendment on outdoor burning bans outdoor fireplaces and portable charcoal or gas grills within 15 feet of any structure holding more than two dwelling units. Leave grilling rules in the house manual so guests know where a grill may go.
Keeping the unit inspection-ready
Permits last a year from issue. Metro's renewal page says its system sends reminder emails 60 and 45 days before expiry, and that renewing on time is the owner's job, not Metro's. Any time you add a bedroom, finish a basement or replace windows, recheck the alarms and escape openings against the list above, because the 2025 fire code requires alarms that meet current rules wherever a permitted alteration touches a dwelling unit or adds a sleeping room.
A simple log helps: the date you tested each alarm, the manufacture date on each, and battery changes. Metro's fire code wants test and service records for required fire protection kept on site, or somewhere approved, for three years.
Who to confirm with
Read this as background, not as legal or engineering advice. Permit questions go to Metro Codes, 615-862-6500. For the fire code itself, the guidelines direct owners to the Nashville Fire Department, 615-862-5421, or FMORequests@nashville.gov. Have a licensed inspector walk the unit before you file, since a failed report delays the permit.
General information from Metro Nashville and State of Tennessee sources, checked October 2026. It is not legal or tax advice. Rules change; confirm with Metro Codes or the agency named before you act.
Questions
My house was built in the 1950s. Does it have to meet newer codes?
For three items, yes. The 2023 inspection guidelines apply 2018 code standards to an old house on alarms and how they link, bedroom windows, and house numbers; everything else may stay as it was legally built. Metro adopted 2024 codes in 2025, so confirm the edition with your inspector.
Can I draw the floor plan myself?
Yes. A sketch you draw is fine if it is accurate, because the inspector checks it against the house and attaches it to the report.
How many guests can a three-bedroom rental take?
Ten. Three bedrooms times two is six, plus four makes ten, under a cap that never goes past 12.
Are battery smoke alarms allowed?
Only if they interconnect. The Fire Department checklist rules out battery-only alarms that cannot link together, and the state rule requires any battery-only alarm in a dwelling to use a ten-year sealed battery.
Does a five-bedroom house qualify if one room is used as an office?
Metro will not permit a unit that has five or more bedrooms. Ask Metro Codes before you apply how it will count a room that could be used for sleeping.
Sources
- Metro Code Chapter 6.28, Short term rental property permit (Municode, version of June 23, 2026)
- Metro Codes, Apply for Short Term Rental Property Permit (updated Oct. 1, 2026; Wayback copy, Nov. 5, 2026)
- Metro Codes, Not-Owner Occupied Permit Application Checklist (Wayback copy, Nov. 5, 2026)
- Metro Codes, STRP Single and Two-Family Dwelling Inspection Guidelines, June 26, 2023 (Wayback copy)
- Metro Codes, Short Term Rental Property Operation Requirements (Wayback copy, Feb. 12, 2026)
- Metro Codes, Renew Short Term Rental Property Permit (Wayback copy, Oct. 12, 2026)
- Metro Council, BL2025-1004, adopting the 2024 International Fire Code and NFPA 101 (Legistar)
- Metro Council, BL2025-898, adopting the 2024 building and residential codes (Legistar)
- Nashville Fire Department, Short Term Rentals Applicant Checklist (Wayback copy)
- Tennessee State Fire Marshal's Office, memo on transient rental homes, April 13, 2023 (Wayback copy)
- Tenn. Comp. R. & Regs. 0780-02-23-.15, Dwelling Units (Cornell LII)
Checked November 12, 2026.
To keep this page, print it or choose Save as PDF in your browser's print window. The printout keeps the sources and the date.
More rules
All 14Historic Overlays and Rental Buildings
A historic overlay in Nashville controls how a building's outside changes.
HOA and Condo Rules on Short-Term Rentals in Tennessee
A Metro permit tells you the city will allow a short-term rental.
Insurance Requirements for Nashville STRs
No rental unit in Nashville gets its permit without a policy on file that protects the property from fire and similar hazards and carries a liability limit of $1 million or higher per incident.