Multi-Unit Buildings and the Fire Code
Units in apartment and condo buildings get their Nashville rental permits signed off by the Fire Marshal's Office, not by an inspector the owner hires. That office has worked from a new local code since October 2025, built on the 2024 editions of the ICC fire code and NFPA 101, and several local amendments speak straight to shared buildings. Here is when that inspection applies, what it looks at, which rules attach to the building as a whole once it holds three or more units, and how to get the visit scheduled. Sources were opened November 12, 2026.
- Who inspects
- Nashville Fire Marshal's Office
- Triggers
- A shared hallway or walkway to the unit; three or more dwellings on the property
- When to request
- After the Codes application exists
- Request by email
- FMORequest@nashville.gov, subject Short Term Rental
- Fire code in force
- 2024 IFC and 2024 NFPA 101, BL2025-1004, passed Oct. 9, 2025
- Exterior numbers on a multifamily building
- 6 inches tall at minimum; unit numbers 3 inches
- Checked
- November 12, 2026
On this page
- When the Fire Marshal inspects
- The fire code the inspector enforces
- What the inspection checks inside each unit
- Smoke alarms under the 2025 amendments
- Numbering the building and each unit
- Grills, balconies and open flames
- Building-wide systems and records
- Requesting the inspection and finishing the permit
- Several units in one building
- Who to confirm with
- Questions
- Sources
When the Fire Marshal inspects
Metro splits the life safety check by building type. Houses and duplexes are certified by a private licensed professional, and Metro Codes says that private certification route stops at two-family homes. Multifamily structures still go to the Fire Marshal. The application page puts it in practical terms: if you reach the unit's door from a common hallway or walkway, plan on the Fire Marshal.
Metro's absentee-owner checklist puts a number on it: a parcel with at least three dwellings. The Fire Department's own page says it inspects multifamily properties that have applied for permits, that its inspection is required to complete the process for them, and that you may schedule once the application is on file with Codes. If your building sits between the two descriptions, such as a duplex with a shared stair, ask the permit desk which route applies before you hire anyone.
The fire code the inspector enforces
Nashville's fire code has changed twice in five years. In April 2021 the Council moved Nashville to the NFPA family of codes with BL2021-658: NFPA 1 as the general fire code and NFPA 101 for some occupancy types, both 2018 editions, later adjusted by BL2022-1373. Then BL2025-1004, passed on third reading October 9, 2025 and effective on passage, replaced that with the 2024 International Fire Code, now called the Metropolitan Fire Prevention Code, together with the 2024 NFPA 101.
Two of its amendments shape how older buildings are judged. If the ICC code is silent on some feature of an older building, the inspector turns to NFPA 101. And the fire code official may accept compliance with a later edition of the code or a referenced standard as meeting the adopted one.
What the inspection checks inside each unit
The department's applicant checklist runs to a short list: street numbering, UL 217 alarms installed to NFPA 72 and linked so all sound at once, and a rescue window for each bedroom. Our fire and life safety page gives the window measurements.
Two details on that checklist deserve a second look in a small apartment. One rule is spacing: an alarm has to be a yard or more away from any air mover, and the checklist counts ceiling fans, return grilles and window air conditioners. Before the visit, check whether a return grille or ceiling fan sits close to the hallway alarm. Wireless interconnected alarms are accepted, but each device has to be programmed, and the checklist warns that the number that can be linked varies by manufacturer.
That checklist's citations still point to the 2012 edition of the ICC fire code, older than both codes Metro has adopted since 2021, so call the office and ask what its inspectors now check.
Smoke alarms under the 2025 amendments
Metro's amended alarm section covers apartment occupancies, Group R-2, along with R-3, R-4 and I-1, and it applies whatever the occupant load. Locations follow the familiar pattern: near the bedrooms outside each sleeping area, in each bedroom, and on every level of the unit.
A new subsection reaches renovation. When an addition, alteration or repair to a dwelling unit or guestroom needs a permit, the unit must get alarms meeting this section, and the same applies whenever a sleeping room is added or created. Exterior surface repairs are exempt. An owner turning a one-bedroom into a two-bedroom before applying for a permit should budget for new alarms in the whole unit.
Numbering the building and each unit
The 2025 code sets address rules for every building in Davidson County. Numbers must be legible from the street that fronts the property, contrast with their background and use Arabic numerals rather than words. On the outside of a multifamily building the numbers or letters must be at least 6 inches tall with a half-inch stroke, and each dwelling unit's own number must be at least 3 inches tall, posted on or at its door.
Check both levels before the visit: the building number as seen from the curb and the unit numbers along every hallway.
Grills, balconies and open flames
Once a building is larger than a duplex, Metro's code keeps any grill, hibachi or other open-flame cooker off balconies and out from under overhangs, and requires 10 feet of clearance from the building for both use and storage. Listed equipment permanently installed under its listing and the manufacturer's instructions is the exception. Metro's open-burning amendment adds a wider buffer for these buildings: portable charcoal or gas grills and outdoor fireplaces stay 15 feet or more from any structure housing three or more households.
In practice, take portable grills off unit balconies and say in the house manual that guests may not bring their own. A shared grill needs a spot that meets the distances, or a permanently installed listed unit.
Building-wide systems and records
Larger buildings bring obligations beyond the unit. Under the amended code, a fire alarm system required by the fire code or the building code must be monitored by an approved central station listed under the current NFPA 72. Records of periodic inspections, tests, servicing and maintenance must be kept on the premises or another approved location for at least three years and handed to the fire code official on request.
The amendments also list operational permits that touch building owners, including one to verify that keys and contact details kept in a building's Knox Box are working and accurate, and one to schedule a fire and life safety inspection outside the department's normal hours. BL2026-1328, passed June 16, 2026, set the Fire Marshal's fees for those two permits at $88 and $350. Starting work that needs a fire prevention permit without one carries a penalty of 300 percent of the permit and inspection fees.
As a buyer, put the monitoring agreement and three years of test and service reports on your document request list. Gaps there are easier to fix before the Fire Marshal visits for the first unit.
Requesting the inspection and finishing the permit
The checklist sets out the steps. Apply with Metro Codes first. Next, write to FMORequest@nashville.gov; type Short Term Rental as the subject, and put your Codes application number, the property address, your name and a callback number in the message. You should receive a confirmation email; the checklist says that if none arrives, the request was not received. The office assigns an inspector, who contacts you to set the appointment.
A passed visit is then entered in Metro's permit system by the inspector, which the checklist says can take two days or more. Metro then emails payment instructions for the $313 permit fee, with a 2.3% charge on card payments. Only then may the unit be advertised. Until that document exists, Metro's checklist says the unit may not appear on any rental website; afterward, each ad carries the permit's number or an image of it.
Several units in one building
Permits attach to single units, so a fourplex needs four applications and four permit fees, and each Fire Marshal request carries its own application number. Each unit may have four bedrooms at most and host one booking group at a time. Neighbor notices, delivered in person or by certified mail, go out per application, and in a stacked building that means the owners of the flats directly upstairs and downstairs as well as those beside.
When several applications are filed at once, ask whether the inspector can see all of them in one trip, and prepare every unit for that date.
Who to confirm with
Read this as general background rather than legal or engineering advice. Metro Codes, 615-862-6500, can say which inspection route your building takes, and the Fire Department, 615-862-5421, can say what its inspectors are checking against this year. A fire protection contractor licensed in Tennessee can test alarms and building systems before the visit.
General information from Metro Nashville and State of Tennessee sources, checked October 2026. It is not legal or tax advice. Rules change; confirm with Metro Codes or the agency named before you act.
Questions
My condo has its own exterior door. Do I still need the Fire Marshal?
Possibly not. Metro's quick test looks at shared corridors, yet its checklist counts dwellings on the parcel, and the two can point different ways for a private-entry unit. Ask the permit desk.
Is it possible to book the Fire Marshal visit first and apply afterward?
No. The Fire Department says the inspection can be scheduled once the application exists at Codes, and the email request has to include the application number.
Which fire code applies to my building now?
Since October 2025, Metro's own amended version of the 2024 ICC fire code, paired with the 2024 Life Safety Code. NFPA 101 fills gaps for existing buildings.
Can guests use a grill on the balcony?
Not a portable one. A listed grill fixed in place is the exception; anything portable is barred from balconies, overhangs and the 10 feet around a building bigger than a duplex.
How long after the inspection until I can list the unit?
Give the inspector's sign-off two days or more to show up in the system, then pay the $313 fee. Listing comes last, once the permit itself is issued.
Sources
- Metro Codes, Apply for Short Term Rental Property Permit (updated Oct. 1, 2026; Wayback copy, Nov. 5, 2026)
- Metro Codes, Not-Owner Occupied Permit Application Checklist (Wayback copy, Nov. 5, 2026)
- Nashville Fire Department, Short Term Rental Inspection Information and Requirements (Wayback copy, Oct. 22, 2026)
- Nashville Fire Department, Short Term Rentals Applicant Checklist (Wayback copy)
- Metro Council, BL2025-1004, 2024 International Fire Code and NFPA 101 (Legistar)
- Metro Council, BL2021-658, 2018 NFPA 1 Fire Code and NFPA 101 (Legistar)
- Metro Council, BL2022-1373, Fire Prevention Code amendments (Legistar)
- Metro Council, BL2026-1328, Fire Marshal's Office fee schedule (Legistar)
- Metro Codes, Short Term Rental Frequently Asked Questions (Wayback copy, Oct. 22, 2026)
- Metro Code Chapter 6.28, Short term rental property permit (Municode, version of June 23, 2026)
Checked November 12, 2026.
To keep this page, print it or choose Save as PDF in your browser's print window. The printout keeps the sources and the date.
More rules
All 14Nashville Hotel Occupancy Tax for STRs
Metro Nashville charges the same hotel occupancy tax on a permitted short-term rental night that it charges on a downtown hotel room: a 7% levy on the guest's bill plus a flat charge for each night, which Metro Finance's return puts at $2.50.
Noise Rules for STR Guests in Nashville
In Nashville the permit holder answers for what short-term rental guests do, and noise is one of the complaint types Metro takes against a specific rental.
Parking Rules for STR Guests
Neighbors can report a short-term rental to Metro over parking just as they can over noise or trash, and the permit carries its own ban on buses, trailers and RVs.